Lubrina 2 Automatic Handpiece Lubrication System (24K325ENG)

MSRP: $3,501.66
$2,815.00
(You save $686.66 )
(No reviews yet) Write a Review
SKU:
PST-JMU-24K325ENG
  • This device automates the maintenance process for dental handpieces, ensuring consistent cleaning and lubrication for up to four instruments at once

Uses:

  • Automatic lubrication and cleaning
    • Routine maintenance:
      • The primary use is the automatic lubrication and cleaning of dental handpieces after each use
      • This removes debris and contaminants that can accumulate during a procedure
    • High-speed handpieces:
      • It services air turbines by purging and lubricating the intricate turbine and bearing mechanisms
      • This is critical for preventing premature wear and tear
    • Low-speed attachments:
      • The system also maintains contra-angles and straight handpieces, including those used for endodontic procedures like the TriAuto ZX2 and Root ZXII 
    • Air scalers: Lubrina 2 can be used for the maintenance of air scalers, ensuring the instrument remains in proper working condition
       
  • Efficiency and time savings
    • Rapid processing:
      • For busy dental practices, a significant use is the ability to service up to four handpieces simultaneously
      • This saves staff time by performing maintenance in a fraction of the time it would take to do manually
    • Consumable cost reduction:
      • The system uses a "clean air-blow" system that removes residual water and excess oil, which can reduce oil consumption by up to 75% compared to manual lubrication
  • Enhanced infection control
    • Thorough purging:
      • Proper cleaning and purging of a handpiece is essential before autoclaving
      • The Lubrina 2's clean air-blow system removes moisture from the interior tubing, which prevents problems during the sterilization process
    • Contamination prevention:
      • By preventing "suck-back," or the backflow of contaminants into the handpiece and dental unit lines, the system enhances patient safety
  • Consistent and reliable maintenance
    • Programmed lubrication:
      • The system's pre-programmed cycles apply the optimal amount of lubricant for each type of handpiece, eliminating the variability and potential for human error associated with manual lubrication
    • Chuck maintenance:
      • For J. Morita instruments, Lubrina 2 has a built-in chuck maintenance function that ensures the handpiece can securely hold burs
  • Versatile compatibility
    • Multi-brand lubricant:
      • The Lubrina 2 accepts multiple brands of spray lubricants, which provides flexibility for practices that use different brands of consumables
    • Universal connections:
      • By using optional adapters, the system can service a wide range of handpiece connections, including 4-hole, 5-hole, and 6-pin

Features:

  • Automatic maintenance:
    • The Lubrina 2 is pre-programmed with the correct lubrication and servicing times for various handpiece types, eliminating the potential for human error that can occur with manual lubrication
      • High capacity:
        • The system can process up to four handpieces at the same time, making it highly efficient for busy dental practices. A single turbine is cleaned in as little as 20 seconds
      • Universal compatibility:
        • The unit is designed to work with various brands of spray lubricant, and it supports different handpiece connections, including 4-hole, 5-hole, and 6-pin
      • Clean air-blow system:
        • This technology uses a dual-conduit design to separate the air and oil streams during the cleaning cycle
        • It effectively removes residual water and surplus oil, which significantly enhances lubrication efficiency and reduces oil consumption by up to 75% compared to manual methods
      • Integrated chuck maintenance:
        • Lubrina 2 includes a built-in function for maintaining the handpiece's chuck, which helps ensure that burs are held securely and extends the life of the instrument
      • Reduced noise:
        • An improved design results in a noise reduction of 15 decibels during operation compared to the original Lubrina model

Benefits:

  • Time and cost savings:
    • Automating the maintenance process saves staff time and significantly reduces oil consumption
  • Increased handpiece longevity:
    • Consistent and thorough maintenance, without the variation of manual processes, helps extend the lifespan of expensive dental handpieces
  • Improved hygiene:
    • The clean air-blow system enhances infection control by ensuring the internal components of the handpiece are properly cleaned and purged
  • Enhanced safety:
    • Proper lubrication and chuck maintenance ensure the handpieces operate correctly and safely during procedures

Contents:

  • Lubrina 2 Automatic Handpiece Lubrication System includes:
    • (1) Morita Lubricant Spray - 420mL
    • (1) Oil Absorbent Pad
    • (1) Oil Absorbent Sheet
    • (2) MORITA Spray Can Stand
    • (1) Power Cord
    • (1) Air Tube
    • (1) Door Oil Absorbent Sheet
    • (1) Front Door Sheet Stopper